info@pro-healthint.com     Phone: +6221 6387 9525

Allied HPI

Features

  • “Positive Click” to starting the time using the tip of a pen or pencil
  • 2 years warranty (no battery included)
  • Battery life up to 3 years
  • Easy battery replacement
  • Time of use is automatically calculated if supplied with oxygen at least 0.5 LPM.
  • Highly accurate time measurement with increments every 0.1 hour.

Part Number

TA30        Limeter Oxygen Timer

TA30-B     Replacement Battery

Timeter® Oxygen Timer

Timeter® Oxygen Timer allows the hospital to calculate the oxygen usage of each patient accurately so that it can be customized billing per patient. With the Timeter® Oxygen Timer, the hospital no longer needs to estimate the use of oxygen per patient and the billing can be adjusted according to actual use.

Specifications

  • Dimension: 11.43 em (height) x 5.08 em (long) x 5.08 em (width)
  • Weight: 265 Grams
  • Inlet fitting: 0xy 9/16″- 18 x 1/8″ NPT DISS Female
  • Outlet fitting: 0xy 9/16″- 18 x 1/8″ NPT DISS Male
  • Sensitivity: Calculation time begins/stops between 0.1-0.5 LPM
  • Maximum Flow: 75 LPM
  • Time calculation accuracy: ±1 minute/month
  • Time calculation range: : 0 – 1999.9 hours with increments every 0.1 hour
  • Battery Type: Button cell battery CR2450 3V Lithium
  • Battery Life: 3 years
  • Warranty: 2 years (no battery included)

Timeter® Flowmeter

Benefits

  • 5 years warranty
  • High and long lasting durability.
  • Complete product range with a choice of body brass and aluminum.
  • Easy Maintenance

Flowmeter Brass

1. Single Oxygen Flowmeter

Model Deskripsi
15001-03 15LPM FLOWMETER
08001-03 8LPM FLOWMETER
15001-03P 15LPM FLOWMETER WITH 1 POWER TAKE OFF
08001-03p 8LPM FLOWMETER WITH 1 POWER TAKE OFF

 

3. Single and Dual Air Flowmeter

Model Deskripsi
15001-13 15LPM DUAL FLOWMETER
15001-13P 15LPM DUAL FLOWMETER WITH 1 POWER TAKE OFF
15001-13Y 15LPM DUAL FLOWMETER WITH Y BAR
15001-03YP1 15LPM DUAL FLOWMETER WITH Y BAR & 1 POWER TAKE OFF
15001-13YP2 15LPM DUAL FLOWMETER WITH Y BAR & 2 POWER TAKE OFF

 

2. Dual Oxygen Flowmeter

Model Deskripsi
15001-03Y 15LPM DUAL FLOWMETER WITH Y BAR
15001-03T 15LPM DUAL FLOWMETER WITH Y BAR
15001-03TP1 15LPM DUAL FLOWMETER WITH Y BAR & 1 POWER TAKE OFF
15001-03YP1 15LPM DUAL FLOWMETER WITH Y BAR & 1 POWER TAKE OFF
15001-03TP2 15LPM DUAL FLOWMETER WITH Y BAR & 2 POWER TAKE OFF
15001-03YP2 15LPM DUAL FLOWMETER WITH Y BAR & 2 POWER TAKE OFF

 

Flowmeter Aluminium

1. Single Oxygen and Air Flowmeter

Model Deskripsi
15001-03-A FLOWMETER ALUMINIUM OXYGEN
15001-13-A FLOWMETER ALUMINIUM AIR

 

Timeter® Classic Flowmeter

Benefits

  • The most complete flowmeter range
  • Detailed scale and rear views ensure high accuracy
  • Long lasting flowmeter
  • 5 years warranty
  • Easy maintenance

AHP300 Ventilator and AHP300P Ventilator

AHP300 and AHP300P offer easy to use a feature that helps you to rapidly choose between 5 saved ventilation protocols. Their complete ventilation capability enables you to ventilate your critical-care patients in emergency and transport situations. AHP300  and AHP300P  give you confidence to overcome any difficult situations.

Accessories

Easy to use

AHP 300 and AHP 300P provide value-added features for transportation within the hospital, between hospitals, as well as transportation outside the hospital:

1. Ventilator with Quick Start option

With saveable settings, the AHP300 and AHP300P allow medical personnel to choose between 5 stored ventilation protocols.

2. Strong battery life

Internal battery p to 7.5 hours of resistance, with an additional battery that can be used up to 21 hours.

3. Oxygen saving use options

Low-pressure oxygen use (oxygen concentrator, liquid oxygen, etc.), can prolong oxygen availability.

Complete Ventilation Capability

  • Invasive and non-invasive ventilation for infants (minimum weight 5 kg) to adults.
  • Ventilation with pressure control or volume control options
  • Options mode SIMV, CPAP, BiPAP
  • FiO2 settings

Benefits

  • Very affordable for daily use in the Hospital
  • Very easy to use (user friendly) and save time (efficient) for medical personnel.
  • Settings consist of Tidal Volume, In Time and Breath per Minute which guarantee a consistent standard of care
  • The air pressure control alarm is too high, the air pressure is too low, the oxygen source is low, and the battery is low which ensures safe use
  • Compact and durable design so it can be used in ambulances, inside or outside the hospital
  • Easy maintanance

EPV200 Portable Ventilator

EPV200 Portable Ventilator with Assist Control

Specifications

Vacutron Suction Regulator

Benefits

  • The only suction regulator that has a safety relief valve as an extra safety system
  • 2 years warranty
  • Complete variant suction regulator for all needs
  • Easy maintenance by rinsing with cold disinfectant
  • Precise and precise vacuum control
  • impact-resistant internal components to guarantee durable quality
  • Inlet and outlet fittings variations to ensure compatibility with existing medical facilities
  • Vacuum setting stability even with fluctuating vacuum sources

Accessories

Gomco Suction

Benefits

  • Strong and durable construction design
  • Easy to use
  • Flexible for a variety of situations and needs
  • Easy maintenance

Accessories

B&F Medical Oxygen Regulator

The oxygen regulator provides several advantages, such as ease of reading flow rates and a click-style controller that makes operation easy. Oxygen regulators are available in several options to suit the user’s needs.

Benefits

  • The uni-body construction is designed to make the regulator strong and prevent breakage.
  • Brass body plated with nickel for safe use in oxygen services
  • Option of the inlet to oxygen cylinder: PIN index inlet for small cylinder and inlet bull nose for a large cylinder.
  • Outlet hose barb or DISS to provide a safe connection to the oxygen supply to the patient.
  • 3.8cm gauge display which is equipped with a guard.
  • Serrated flow control knob for easy flow rate selection.
  • Large flow control figure and easy to read
Number Part Installation

1. PIN INDEX Regulator Model

For Hospital and Homecare Use

  • 21020 0-6 l/min, Outlet Hose Barb, with pressure display
  • 22020 0-6 l/min, Outlet DISS, with pressure display
  • 21014 0-8 l/min, Outlet Hose Barb, with pressure display
  • 23014 0-8 l/min, Outlet DISS, with pressure display
  • 21007 0-15 l/min, Outlet Hose Barb, without pressure display
  • 21017 0-15 l/min, Outlet Hose Barb, with pressure display
  • 23017 0-15 l/min, Outlet DISS, with pressure display
  • 21030 0-25 l/min, Outlet Hose Barb, with pressure display
  • 21031 0-25 l/min, Outlet DISS, without pressure display

For Emergency Medical Service Use (to be connected to another device, such as EPV200 Portable ventilator)

  • 21012 0-15 l/min, 2 Check Valve, Outlet Hose Barb, with pressure display
  • 24017 0-15 l/min, 1 Check Valve, Outlet Hose Barb, with pressure display
  • 21025 0-25 l/min, 2 Check Valve, Outlet Hose Barb, with pressure display
  • 21032 0-25 l/min, 1 Check Valve, Outlet Hose Barb, with pressure display

2. Bull Nose Regulator Model

For Hospital and Homecare Use

  • 23020 0-6 l/min, Outlet Hose Barb, with pressure display
  • 23002 0-8 l/min, Outlet DISS, with pressure display
  • 23003 0-15 l/min, Outlet Diss, with pressure display

For Emergency Medical Service Use (to get connected to another device, such as EPV200 Portable ventilator)

  • 23004 0-15 l/min, 1 Check Valve, Outlet Hose Barb, with display pressure
  • 23006 0-15 l/min, 2 Check Valve, Outlet Hose Barb, with display pressure
  • 23025-G 0-15 l/min, 2 Check Valve, Outlet Hose Barb, with display pressure

Specifications

1. Supply Pressure: 500 up to 2200 psi

2. Outlet Flow:

  • Outlet High Flow: 40 up to 60 psi on inlet pressure 500 up to 2200 psi

3. Flow Capacity:

  • Outlet High Flow: Minimum 100 l/min with single or combined, on inlet pressure 500 psi
  • Constant Flow Outlet Options:

       0-6 l/min: 0, 0.125, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6

       0-8 l/min: 0, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8

       0-15: l/min: 0, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 8, 10, 15

       0-25 l/min: 0, 1, 2, 4, 6, 8, 10, 12, 15, 18, 20, 25

3. Filter: 50 micron sintered bronze

4. Safety Relief Pressure: 75-140 psi

5. Operating Temperature: 00C up to 00C

6. Storage Temperature: -280C up to 480C

7. Material:

  • Body: Brass
  • Knob: Polymer ABS
  • Outlet: Brass covered with nickel
  • Internal Part: Brass, Stainless Steel, Viton, Silicon, and Teflon